Chilled Water Cooling Systems Reports

Monitoring the Computer Room's Physical Environment
sponsored by Sensaphone
WHITE PAPER: This paper addresses the greatest environmental threats to the functionality of small to medium computer rooms and presents the time and cost savings associated with the integration of a remote monitoring system.
Posted: 22 Apr 2008 | Published: 22 Apr 2008

Sensaphone

Cooling Cost-Saving Strategies: Comfort Cooling vs. Precision Cooling
sponsored by Emerson Network Power
WHITE PAPER: Important differences exist between precision cooling and building air conditioning (comfort cooling) in controlling these environmental conditions. In this paper, we compare both cooling systems’ ability to maintain favorable environmental conditions, and their energy efficiency and annual operating costs.
Posted: 11 Oct 2010 | Published: 11 Oct 2010

Emerson Network Power

Liebert: The Right Cooling for IT Environments
sponsored by Emerson Network Power
WHITE PAPER: Many IT professionals are finding that dedicated precision cooling is the right solution to provide the ideal environment for sensitive electronics. Read this paper to learn why precision cooling is the optimal choice for keeping data centers cool in the most cost-effective way.
Posted: 13 Jul 2010 | Published: 13 Jul 2010

Emerson Network Power

Humidification Stratiegies for Data Centers and Network Rooms
sponsored by Schneider Electric
WHITE PAPER: This paper explains the nature of humidity, its effects and its management in computer rooms and data centers.
Posted: 26 Mar 2014 | Published: 20 Nov 2008

Schneider Electric

Impact of High Density Hot Aisles on IT Personnel Work Conditions
sponsored by Schneider Electric
WHITE PAPER: This white paper discusses the issue of increasing discomfort for computer room workers in high power density data centers.
Posted: 10 Oct 2013 | Published: 10 Oct 2013

Schneider Electric

Performance that Adapts to Your Business Environment - Intel® Xeon® Processor 5500 Series Intelligently Scales Performance and Energy Use
sponsored by Insight & Intel
TECHNICAL ARTICLE: Servers based on the Intel® Xeon® processor 5500 series provide a foundation for IT management to refresh existing or design new data centers, achieving greater performance and energy efficiency.
Posted: 06 Oct 2009 | Published: 06 Oct 2009

Insight & Intel

How Monitoring Systems Reduce Human Error in Distributed Server Rooms and Remote Wiring Closets
sponsored by Schneider Electric
WHITE PAPER: Surprise incidences of downtime in server rooms and remote wiring closets lead to sleepless nights for many IT managers. This paper analyzes several of these incidents and makes recommendations for how a basic monitoring system can help reduce the occurrence of these unanticipated events.
Posted: 26 Jan 2011 | Published: 26 Jan 2011

Schneider Electric

Case Study: Arnold Worldwide Enjoys Cost Savings and Scalability
sponsored by DellEMC and Intel®
WHITE PAPER: Arnold Worldwide is a Boston-based global advertising agency. They needed to replace its existing SAN with virtualized storage. Read this case study to learn how Arnold successfully addressed their DR and scalability needs, but also reduced its data center footprint and slashed its power and cooling costs.
Posted: 05 Apr 2012 | Published: 30 Nov 2011

DellEMC and Intel®

Energy Logic: Reducing Data Center Energy Consumption by Creating Savings that Cascade Across Systems
sponsored by Emerson Network Power
WHITE PAPER: Energy Logic is a vendor-neutral roadmap for optimizing data center energy efficiency that starts with the IT equipment and progresses to the support infrastructure. This paper shows how it can deliver a 50 percent or greater reduction in data center energy consumption without compromising performance or availability.
Posted: 21 Jan 2010 | Published: 21 Jan 2010

Emerson Network Power

Piecing Together the Right Server Environment
sponsored by Curvature
EGUIDE: From power distribution outlets to available network connectivity, server deployment can be an arduous process. Explore ten considerations that should be factored into every rack-and-stack server deployment checklist and learn the differences between converged infrastructures and disaggregated servers.
Posted: 29 Aug 2016 | Published: 25 Aug 2016

Curvature